For faster execution of reinforcement joints
- Standard length 1.25 m, height of the box: 30 mm
- Significant advantages for the planner:
Excellent concrete bonding owing to perforated beaded strip - Significant advantages on the building site:
COMAX® P speeds up completion of shuttering owing to tear-off cover
- no tools needed - COMAX® P - KOMO certified
- COMAX® P - robust and very strong
- COMAX® P is highly compatible with the BETOMAX® injection system
- Practically no restriction of injected material
- DIN 1045-1 states that the load capacity utilization of casings must not exceed 80%
Agenda:
B = Type/strip width/element width
l = Anchoring length
b = Stirrup width
h = Stirrup height
e = Stirrup spacing
- Standard length 1.25 m
- Toothing in longitudinal direction for optimal force transmission
- COMAX® Q for exposure to shear forces vertical to the joint
- Significant advantages for planners: acc. to DIN 1045-1 the COMAX® Q is classed as "TOOTHED"
- Dimensionally stable cover facilitates short striking times
- Special types (except K and BK) available on request
Shear force applied vertical to lift joint
Formulas and tables
- Standard length 1.25 m
- Toothing in transverse direction for optimal force transmission
- COMAX® L for exposure to longitudinal shear forces parrallel to the joint
- Significant advantages for planners:
acc. to DIN 1045-1 the COMAX® L is classed as "TOOTHED" - Dimensionally stable cover facilitates short striking times
- Special types (except K and BK) available on request
Shear force applied parallel to lift joint
Formulas and tables
As part of its proven standard range, BETOMAX® also supplies various special COMAX® P, Q, L types with the following parameters:
- COMAX® P Element lengths up to 2.50 m
- COMAX® Q and L Element lengths up to 1.25 m
- Element/strip width (B) for COMAX® P 60, 80, 110, 140, 160, 190, 220 and 240 mm
- Element/strip width (B) for COMAX® Q and L 110, 140, 160, 190 and 240 mm
- Box height: COMAX® P: 30 mm
- Box height: COMAX® Q and L: 40 mm
- Stirrup types as per drawing (see at working example)
- Steel Ø 8, 10 and 12 mm, Ø 6 and 14 mm available on request
- Standard stirrup spacing 15, 20 and 25 cm
- Variable stirrup spacing (e) available
- Stirrup width (b) always 2 cm less than selected element width in one strip
- DIN 1045-1 states that the load capacity utilization of casings must not exceed 80%
PU magnet for securing COMAX® to steel shuttering.Easily applied and removed thanks to screw thread.
Benefits:
- Extremely powerful magnet: 4 magnets per 1.25 m element, 6 magnets per 2.50 m element
- Special shape - with groove - exact fit for COMAX® P
- Highly resistant: may be re-used up to ten times
- Easily employed - tools or aids not required. Removal with the help of the embedded screw thread.
- Suitable for pre-cast sections and construction sites