...safety without compromise

SD Water Stop

Swelling-active SD water stop reliably prevents lateral water infiltration. Is fitted with the BETOMAX® SD installation pliers 

  • New type of sealing ring on a synthetic elastomer basis
  • Automatic swelling responds to moisture and wetness
  • Defined swelling capacity designed specificially for sealing purposes
  • Universally applicable with fiber-reinforced concrete, steel distance tubes and plastic tubes with diameters ranging from 22 to 40 mm
  • Simplest installation and reliable handling with the special BETOMAX® SD installation piers

Calculation of tube cut length Dist FB 22. Dist K-22 and Dist ST-22 (L): L = WD - 2c

Tube length must be ordered separately. 

Water stop, welded on

120 x 120 mm square water stop ensures water impermeability. Studs improve bonding with concrete.
WD = wall thickness

Calculation of tie rod cut length (L):
 L = WD - 2c

Cut length
rod must be ordered separately.

Applications, properties and benefits
  • 120 x 120 mm square water stop offers best protection against infiltration of water
  • Water stop with studs improves bonding with concrete and resistance to torsional stress. Compliance with striking time is essential.
  • Conical holes can be closed with mortar or a concrete plug when the cone is removed
  • In conjunction with Cone EX, the concrete cover c for example is 35 or 50 mm
  • Concrete cover c with MKK® B 15 is 50 mm

Water stop B 15 round

Compatible with Uni 15. The water stop B 15 has two sockets for accommodating Dist K - 26 rough cut tubes with a tight seal. This prevents wet cement from entering and concreting in the tie rod. Reducing adapters are available for Dist K-22 and Dist FB-22. The 70 mm dimension becomes 125 mm if the reducing adapter is used.


Calculating of tie tube cut length (L):
LK-26 = (WD - 2c - 70) / 2

Calculating of tube cut length (L) with reducing adapter and K 22 / FB 22:
LK-22/FB 22 = (WD - 2c - 125) / 2

    Applications, properties and benefits
    • Molded round water-stop plat, 120 mm diameter, ensures greatest possible protection against lateral infiltration of water.
    • Conical holes may be sealed with mortar or glued with conrete plugs once the cone has been removed. 
    • In conjunction with Cone EX, the concrete cover is 35 or 50 mm.
    • Concrete Cover c with MKK® B 15 is 50 mm.

    Water stop B 15   

    Compatible with Uni 15. The water stop B 15 has two sockets for accommodating Dist K-26 rough cut tubes with a tight seal. This prevents wet cement from entering and concreting in the tie rod. Studs improve bonding with concrete. Reducing adapters are available for Dist K-22 and Dist FB-22. The 70 mm dimension becomes 125 mm if a reducing adapter is used.

    WD = wall thickness.

    Calculation of tube cut length (L):
    LK-26 = (WD - 2c - 70) / 2

    Calculation of tube cut length (L)
    with reducing adapter and K22 or FB 22:
     
    LK-22/FB 22 = (WD - 2c - 125) / 2

    Applications, properties and benefits:
    • 120 x 120 mm square water stop offers best protection against infiltration of water
    • Water stop with studs improves bonding with concrete and resistance to torsional stress. Compliance with striking time is essential.
    • Conical holes can be closed with mortar or a concrete plug when the cone is removed
    • In conjunction with Cone EX, the concrete cover c for example is 35 or 50 mm
    • Concrete cover c with MKK® B 15 is 50 mm

    Water stop St 22, welded on

    On Dist St-22. Prevents infiltration of water. The steel tube is closed watertight with the FLUPP St plug. Cone EX with 35 or 50 mm cover. Once the cone is removed, the conical hole has to be closed with mortar or a concrete plug.

    Calucaltin of tube cut length (L):   L = WD - 2c

    Cut length of tube must be ordered separately.


    Applications, properties and benefits:
    • 120 x 120 mm square water stop offers best protection against infiltration of water
    • Water stop with studs improves bonding with concrete and resistance to torsional stress. Compliance with striking time is essential.
    • Conical holes can be closed with mortar or a concrete plug when the cone is removed
    • In conjunction with Cone EX, the concrete cover c is 35 or 50 mm
    • Concrete cover c with MKK® B 15 is 50 mm