...no chance for pressurised water

Monomax injection system

General German building authority test certificate (in German)

Ever-greater importance is being attached to sealing concrete structures. Although construction joints are unavoidable in structural components for design and practical reasons, the damage that is often caused by moisture at such locations can be avoided. The extent of work and costs associated with remedial work are high. The growing awareness of quality and durability calls for new design solutions that guarantee long-term protection against penetration.

Application:
Waterproofing and non-positive connection of construction joints

MONOMAX injection hose for injecting:
  • PUR resin (Corresponds to P-PUR in the test certificate)
  • AC-Gel
  • P-AC gel
  • P microcement (ultra-fine cement)
  • PUR foam
  • Epoxy resin

Allows multiple injection, e.g. with ultra-fine cement and acrylate gel, subject to thorough flushing of the transportation channel after each injection.

Features:
  • Very flexible and easy to lay
  • Resists penetration by foreign substances
Construction:
  • Foamed plastic injection hose
  • Orifices in the form of micro-slots evenly distributed around the circumference
Connecting:
  • Duobox for connecting two hoses; standard depth for concrete cover 30 mm, other depths on request
  • Hose end box (for ready-made hose with Quicky and fabric-reinforced PVC hose)
Hose mounting:
  • Stecki plastic fastener
  • MONOMAX hose clamps with cap-head bolts/impact plug

P400 injection system      

Inspection Report (in German)

Ever-greater importance is being attached to sealing concrete structures. Although construction joints are unavoidable in structural components for design and practical reasons, the damage that is often caused by moisture at such locations can be avoided. The extent of work and costs associated with remedial work are high. The growing awareness of quality and durability calls for new design solutions that guarantee long-term protection against penetration.

Application:Waterproofing construction joints P400 injection hose encased in bentonite, which swells on contact with water

P400 injection hose for injecting:
  • PUR resin
  • PUR foam
  • Epoxy resin
  • Acrylate gel

Allows multiple injection, e.g. with acrylate gel

Features:
  • Swells on contact with water
  • Initially no injection required as a general rule
  • Can be activated by filling hose with water
  • Resists penetration by foreign substances
  • Full surface contact
  • Ready-made in 5 m lengths
Sheath construction:
  • Sheath of swelling bentonite (based on natural clay) fully surrounding the hose
Injection hose construction:
  • Plasticized PVC injection hose with multiple functional features
  • Internal transportation channel surrounded by four secondary channels
  • Orifices in the form of micro-slots in linear arrangement with buffer zones to facilitate valve function
Connecting:
  • Duobox for connecting two hose ends; standard depth for concrete cover 30 mm
  • Nailed fitting
  • Hose end box
Hose mounting:
  • Betoquell levelling paste for gluing and levelling
  • FUMAX® contact adhesive
  • BETOFIX for gluing